PL128200 Li-Ion, Li-pol Battery Charger |
| ITEM |
Specification |
Symble |
Parameters |
Notes |
|
INPUT |
|
| 1 |
Rated Input |
V ac |
100~240Vac 50/60Hz |
|
| 2 |
Input Range |
V ac |
90~264Vac |
|
| 3 |
Input Current |
I in |
0.5Arms |
220V OUTPUT: Full load |
| 4 |
Max Inout Power |
P in |
38.00 |
|
|
OUTPUT |
|
| 5 |
Series batteries |
PCs |
3 |
|
| 6 |
Rated Output |
V rate |
12.75 |
|
| 7 |
Output Range |
V out |
7.5 ~ 12.9 |
|
| 8 |
Rated Current |
I rate |
2 |
|
| 9 |
Current Range |
I out |
1.8 ~ 2.4A |
|
| 10 |
Suit for Batt Capacity |
Ah |
2 ~ 20 AH NiMH/NiCd |
|
| 11 |
Trickle Current |
A |
0.2 ~ 0.6→0 |
|
| 12 |
Short Current |
A |
1A |
|
| 13 |
Max Output Power |
W |
30.96 |
|
| 14 |
Charging Mode |
|
Continuously |
|
| 15 |
Fast chaging finish Parameters |
A |
Current Change to 0.1-0.3C |
|
| 16 |
Duel color LED (RED & GREEN) |
|
Charging--RED, No battery or Charging finished(Trickle on)--GREEN Output short --RED&GREEN Blinking |
| 17 |
Effiency |
% |
~ 80% |
At max. load |
|
Environment |
|
| 18 |
Ambient Temp. |
°C |
-10 ~ +40 |
Full load & natural convection. |
| 19 |
Ambinet Humidity |
%RH |
< 90 % |
Relative humidity, non-condensing. |
| 20 |
Storage Temp. |
°C |
-40 ~ +70 |
|
| 21 |
Storage Humidity |
%RH |
0 ~ 95 % |
Relative humidity, non-condensing. |
| 22 |
Cooling Mode |
- |
Natural |
Natural convection |
| 23 |
Vibration |
|
5mm, 50Hz, 600S |
Non-operating condition. |
| 24 |
Drop Test |
|
0.8M drop test, 3 times. |
Non-operating condition. |
|
Mechanical |
|
| 25 |
Weight |
g |
|
|
| 26 |
Case Size |
mm |
|
refer to www.chargercn.com |
| 27 |
Input Plug |
- |
Customer difine |
refer to www.chargercn.com |
| 28 |
Output Plug |
|
Customer difine |
refer to www.chargercn.com |
|
Security |
|
| 29 |
Case Temp. Rising |
°C |
< 40 on casing |
At 220V& Max. Load |
| 30 |
LVD |
- |
CE-LVD, 3C, UL |
some models |
| 31 |
EMC |
- |
CE-EMC, FCC, 3C, UL |
some models | |
|